Jual Leak Detector WJL-6000 ELITECH (Halogen Detector) dengan harga Rp234.000 dari toko online Ultra 2000, Jakarta Pusat. Cari produk Produk Lainnya lainnya di Tokopedia. Jual beli online aman dan nyaman hanya di Tokopedia. Elitech WJL-6000 is our new product with the stable function and small appearance; It is an ideal and economic halogen leak detector. Under normal working circumstance, the detector will beep when it’s turned on. It is different with the rapid sound of warning alarm. Applications: The WJL-6000 can also be used to. Work with WJL-6000 and CLD100. Quantity: 1 pcs. Elitech Technology, Inc. Located in Milpitas California United States. 3 x Fluorine Hose. Refrigerant Leak Detector 1 x WJL-6000S Leak Detector. Digital Refrigeration Manifold Gauge Battery Life: six months.
Application: It will respond to all halogenated (contains Chlorine of Fluorine) refrigerants. This includes, but is not limited to:
CFCs e.g.R12, R11,R500,R503 etc. HCFCs e.g. R22,R123, R124,R502 etc. HFCs e.g. R134a, R404s, R125 etc.
Blends such asAZ-50. HP62. MP39 etc.
Detect Ethylene Oxide gas leaks in hospital sterilizing equipment (it will detect the halogenated carrier gas).
Detect SF-6 in high voltage circuit breakers.
Detect most gases that contain chlorine, fluorine and bromine (halogen gases). Detect cleaning agents used in dry cleaning applications such as per chloroethylene. Detect halogen gases in fire-extinguishing system.
The Elitech WJL-6000 Halogen Leak Detector is incorporated with advanced leak detect technology. It's an ideal and economic halogen leak detector.
Main features: • Detect all kinds of halogen refrigerant gases;
• Sensitivity adjusted at any time and it can be adjusted automatically to the best state of detecting;
• Inner precise IC with ultra-low power consumption circuit design, more stable, longer battery life;
• Dual-color visual display of battery voltage;
• Excellent sensor,high sensitivity,long lifetime.
Halogen Leak Detector Wjl-6000 Manual
Technical parameters: •operating temperature: o c-52 c (30°F to 125°F);
•Maximum sensitivity: 6 g/yr,for all halogenated refrigerants;
•Response time:Instantaneous ;
•Fixed probe length: 20cm;
Wjl 6000 Manual Treadmill
•Dimensions:22.9*6.5*6.5 (cm);
Wjl 6000 Manual
Wjl 6000 Manual Typewriters
•Reset time: two to ten seconds;
Wjl 6000 Manual Transfer Switch
•Power supply 6V DC, four AAA alkaline batteries.